info@trigasdm.com | +49 8165 9999300 | xing

DM-Series Turbinen FlowmetersTrigasDM turbine flowmeters are well suited for a wide range of applications. These include among others, monitoring of flow rates of gasoline and coolant or lubricants in automotive and aerospace engines, measuring injection of additives in the food and pharmaceutical industries, monitoring and measurement of high-purity water in the research and development area, volume measurement for consumption billing etc.

Innovative helical rotor blade design for improved linearity and reduced pressure loss.

Der Rotor einer Durchflussmessturbine

Advantages:

  • New rotor design for better linearity and 15% less pressure loss
  • Error-free digital pulse output
  • Precision ball bearings for better repeatability and optimal results at lower flow rates
  • Measureing range 0,05 to 1700 l/min
  • Pickoffs with integrated temperature sensors
  • Compatible with Cox AN/ANC and Flow Technology FT/NT Series

Technical Data:
– Linear Flow Range: 0,5 l/min to 5 l/min (0.13 GPM to 1.3 GPM)
– Extended Flow Range: 0,05 l/min to 5,5 l/min (0.013 GPM to 1.5 GPM)
– Operating Pressure: up to 540 bar
– Pressure Loss (at 70% linear flow): 0,08 bar
– Temperature Range: -270°C to 400°C (-454°F to 752°F)
– Response Time: <3 ms
– Calibration Accuracy: ≤±0,03% of measurement
– Repeatability: ≤±0,05% of measurement
– Linearity in Linear Flow Range: ≤±2% of measurement
– Linearity with Linearizer: ≤±0,1% of measurement
– K-Factor: 22600 Impulse/l
– Max. Frequency: 2300 Hz
– Housing and Turbine Material: Stainless Steel
– Ball Bearing Material: Ceramic bearings, Steel cage
– Weight: 161 g
– Inner Diameter: 7,6 mm
– Length: 62,2 mm
– Connection: AN threaded connection
– Connection Size: ½“
– Connection Thread: ¾“ -16UNJF-3A
– Recommended Prefiltration: 10µ
– Recommended Inlet: 76 mm
– Recommended Outlet: 38 mm

Technical Data:
– Linear Flow Range: 0,95 l/min to 12 l/min (0.25 GPM to 3.2 GPM)
– Extended Flow Range: 0,1 l/min to 13 l/min (0.03 GPM to 3.4 GPM)
– Operating Pressure: up to 540 bar
– Pressure Loss (at 70% linear flow): 0,19 bar
– Temperature Range: -270°C to 400°C (-454°F to 752°F)
– Response Time: <3 ms
– Calibration Accuracy: ≤±0,03% of measurement
– Repeatability: ≤±0,05% of measurement
– Linearity in Linear Flow Range: ≤±0,5% of measurement
– Linearity with Linearizer: ≤±0,1% of measurement
– K-Factor: 8700 Impulse/l
– Max. Frequency: 1950 Hz
– Housing and Turbine Material: Stainless Steel
– Ball Bearing Material: Ceramic bearings, Steel cage
– Weight: 161 g
– Inner Diameter: 7,6 mm
– Length: 62,2 mm
– Connection: AN threaded connection
– Connection Size: ½“
– Connection Thread: ¾“ -16UNJF-3A
– Recommended Prefiltration: 10µ
– Recommended Inlet: 76 mm
– Recommended Outlet: 38 mm

Technical Data:
– Linear Flow Range: 1,9 l/min to 20 l/min (0.5 GPM to 5.3 GPM)
– Extended Flow Range: 0,2 l/min to 24 l/min (0.05 GPM to 6.3 GPM)
– Operating Pressure: up to 450 bar
– Pressure Loss (at 70% linear flow): 0,163 bar
– Temperature Range: -270°C to 400°C (-454°F to 752°F)
– Response Time: <3 ms
– Calibration Accuracy: ≤±0,03% of measurement
– Repeatability: ≤±0,05% of measurement
– Linearity in Linear Flow Range: ≤±0,5% of measurement
– Linearity with Linearizer: ≤±0,1% of measurement
– K-Factor: 4860 Impulse/l
– Max. Frequency: 2000 Hz
– Housing and Turbine Material: Stainless Steel
– Ball Bearing Material: Ceramic bearings, Steel cage
– Weight: 154 g
– Inner Diameter: 9,4 mm
– Length: 62,2 mm
– Connection: AN threaded connection
– Connection Size: ½“
– Connection Thread: ¾“ -16UNJF-3A
– Recommended Prefiltration: 10µ
– Recommended Inlet: 94 mm
– Recommended Outlet: 47 mm

Technical Data:
– Linear Flow Range: 2,8 l/min to 33 l/min (0.74 GPM to 8.7 GPM)
– Extended Flow Range: 0,3 l/min to 38 l/min (0.08 GPM to 10 GPM)
– Operating Pressure: up to 410 bar
– Pressure Loss (at 70% linear flow): 0,3 bar
– Temperature Range: -270°C to 400°C (-454°F to 752°F)
– Response Time: <3 ms
– Calibration Accuracy: ≤±0,03% of measurement
– Repeatability: ≤±0,05% of measurement
– Linearity in Linear Flow Range: ≤±0,5% of measurement
– Linearity with Linearizer: ≤±0,1% of measurement
– K-Factor: 3720 Impulse/l
– Max. Frequency: 2100 Hz
– Housing and Turbine Material: Stainless Steel
– Ball Bearing Material: Ceramic bearings, Steel cage
– Weight: 150 g
– Inner Diameter: 10,2 mm
– Length: 62,2 mm
– Connection: AN threaded connection
– Connection Size: ½“
– Connection Thread: ¾“ -16UNJF-3A
– Recommended Prefiltration: 10µ
– Recommended Inlet: 102 mm
– Recommended Outlet: 51 mm

Technical Data:
– Linear Flow Range: 3 l/min to 40 l/min (0.79 GPM to 10.6 GPM)
– Extended Flow Range: 0,4 l/min to 48 l/min (0.11 GPM to 12.7 GPM)
– Operating Pressure: up to 410 bar
– Pressure Loss (at 70% linear flow): 0,21 bar
– Temperature Range: -270°C to 400°C (-454°F to 752°F)
– Response Time: <3 ms
– Calibration Accuracy: ≤±0,03% of measurement
– Repeatability: ≤±0,05% of measurement
– Linearity in Linear Flow Range: ≤±0,5% of measurement
– Linearity with Linearizer: ≤±0,1% of measurement
– K-Factor: 2450 Impulse/l
– Max. Frequency: 1950 Hz
– Housing and Turbine Material: Stainless Steel
– Ball Bearing Material: Ceramic bearings, Steel cage
– Weight: 148 g
– Inner Diameter: 11,2 mm
– Length: 62,2 mm
– Connection: AN threaded connection
– Connection Size: ½“
– Connection Thread: ¾“ -16UNJF-3A
– Recommended Prefiltration: 10µ
– Recommended Inlet: 112 mm
– Recommended Outlet: 56 mm

Technical Data:
– Linear Flow Range: 4,5 l/min to 60 l/min (1.2 GPM to 16 GPM)
– Extended Flow Range: 0,6 l/min to 70 l/min (0.16 GPM to 18.5 GPM)
– Operating Pressure: up to 410 bar
– Pressure Loss (at 70% linear flow): 0,61  bar
– Temperature Range: -270°C to 400°C (-454°F to 752°F)
– Response Time: <3 ms
– Calibration Accuracy: ≤±0,03% of measurement
– Repeatability: ≤±0,05% of measurement
– Linearity in Linear Flow Range: ≤±0,5% of measurement
– Linearity with Linearizer: ≤±0,1% of measurement
– K-Factor: 1710 Impulse/l
– Max. Frequency: 2000 Hz
– Housing and Turbine Material: Stainless Steel
– Ball Bearing Material: Ceramic bearings, Steel cage
– Weight: 282 g
– Inner Diameter: 12,8 mm
– Length: 69,1 mm
– Connection: AN threaded connection
– Connection Size: ¾“
– Connection Thread: 7/8“ -14UNJF-3A
– Recommended Prefiltration: 10µ
– Recommended Inlet: 128 mm
– Recommended Outlet: 64 mm

Technical Data:
– Linear Flow Range: 7,6 l/min to 90 l/min (2 GPM to 23.8 GPM)
– Extended Flow Range: 0,9 l/min to 95 l/min (0.24 GPM to 25.1 GPM)
– Operating Pressure: up to 410 bar
– Pressure Loss (at 70% linear flow): 0,64 bar
– Temperature Range: -270°C to 400°C (-454°F to 752°F)
– Response Time: <3 ms
– Calibration Accuracy: ≤±0,03% of measurement
– Repeatability: ≤±0,05% of measurement
– Linearity in Linear Flow Range: ≤±0,5% of measurement
– Linearity with Linearizer: ≤±0,1% of measurement
– K-Factor: 1260 Impulse/l
– Max. Frequency: 2000 Hz
– Housing and Turbine Material: Stainless Steel
– Ball Bearing Material: Ceramic bearings, Steel cage
– Weight: 383 g
– Inner Diameter: 14,3 mm
– Length: 82,6 mm
– Connection: AN threaded connection
– Connection Size: ¾“
– Connection Thread: 1-1/16“ -12UNJ-3A
– Recommended Prefiltration: 10µ
– Recommended Inlet: 143 mm
– Recommended Outlet: 72 mm

Technical Data:
– Linear Flow Range: 19 l/min to 220 l/min (5 GPM to 58.1 GPM)
– Extended Flow Range: 2,2 l/min to 240 l/min (0.58 GPM to 63.4 GPM)
– Operating Pressure: up to 350 bar
– Pressure Loss (at 70% linear flow): 0,39 bar
– Temperature Range: -270°C to 400°C (-454°F to 752°F)
– Response Time: <3 ms
– Calibration Accuracy: ≤±0,03% of measurement
– Repeatability: ≤±0,05% of measurement
– Linearity in Linear Flow Range: ≤±0,5% of measurement
– Linearity with Linearizer: ≤±0,1% of measurement
– K-Factor: 550 Impulse/l
– Max. Frequency: 2200 Hz
– Housing and Turbine Material: Stainless Steel
– Ball Bearing Material: Ceramic bearings, Steel cage
– Weight: 550 g
– Inner Diameter: 21,9 mm
– Length: 90,4 mm
– Connection: AN threaded connection
– Connection Size: 1“
– Connection Thread: 1-5/16“ -12UNJ-3A
– Recommended Prefiltration: 20µ
– Recommended Inlet: 219 mm
– Recommended Outlet: 110 mm

Technical Data:
– Linear Flow Range: 34 l/min to 400 l/min (9 GPM to 106 GPM)
– Extended Flow Range: 3,8 l/min to 490 l/min (1 GPM to 130 GPM)
– Operating Pressure: up to 350 bar
– Pressure Loss (at 70% linear flow): 0,62 bar
– Temperature Range: -270°C to 400°C (-454°F to 752°F)
– Response Time: <3 ms
– Calibration Accuracy: ≤±0,03% of measurement
– Repeatability: ≤±0,05% of measurement
– Linearity in Linear Flow Range: ≤±0,5% of measurement
– Linearity with Linearizer: ≤±0,1% of measurement
– K-Factor: 245 Impulse/l
– Max. Frequency: 2000 Hz
– Housing and Turbine Material: Stainless Steel
– Ball Bearing Material: Ceramic bearings, Steel cage
– Weight: 957 g
– Inner Diameter: 25,4 mm
– Length: 103 mm
– Connection: AN threaded connection
– Connection Size: 1 1/4“
– Connection Thread: 1-5/8“ -12UNJ-3A
– Recommended Prefiltration: 20µ
– Recommended Inlet: 254 mm
– Recommended Outlet: 127 mm

Technical Data:
– Linear Flow Range: 57 l/min to 700 l/min (15.1 GPM to 185 GPM)
– Extended Flow Range: 6 l/min to 820 l/min (1.6 GPM to 217 GPM)
– Operating Pressure: up to 250 bar
– Pressure Loss (at 70% linear flow): 0,86 bar
– Temperature Range: -270°C to 400°C (-454°F to 752°F)
– Response Time: <3 ms
– Calibration Accuracy: ≤±0,03% of measurement
– Repeatability: ≤±0,05% of measurement
– Linearity in Linear Flow Range: ≤±0,5% of measurement
– Linearity with Linearizer: ≤±0,1% of measurement
– K-Factor: 110 Impulse/l
– Max. Frequency: 1500 Hz
– Housing and Turbine Material: Stainless Steel
– Ball Bearing Material: Ceramic bearings, Steel cage
– Weight: 1208 g
– Inner Diameter: 33,4 mm
– Length: 116,6 mm
– Connection: AN threaded connection
– Connection Size: 1 1/2“
– Connection Thread: 1-7/8“ -12UNJ-3A
– Recommended Prefiltration: 20µ
– Recommended Inlet: 334 mm
– Recommended Outlet: 167 mm

Technical Data:
– Linear Flow Range: 83 l/min to 1100 l/min (21.9 GPM to 291 GPM)
– Extended Flow Range: 10 l/min to 1300 l/min (2.6 GPM to 344 GPM)
– Operating Pressure: up to 250 bar
– Pressure Loss (at 70% linear flow): 0,34 bar
– Temperature Range: -270°C to 400°C (-454°F to 752°F)
– Response Time: <3 ms
– Calibration Accuracy: ≤±0,03% of measurement
– Repeatability: ≤±0,05% of measurement
– Linearity in Linear Flow Range: ≤±0,5% of measurement
– Linearity with Linearizer: ≤±0,1% of measurement
– K-Factor: 65 Impulse/l
– Max. Frequency: 1400 Hz
– Housing and Turbine Material: Stainless Steel
– Ball Bearing Material: Ceramic bearings, Steel cage
– Weight: 2614 g
– Inner Diameter: 44,5 mm
– Length: 154 mm
– Connection: AN threaded connection
– Connection Size: 2“
– Connection Thread: 2-1/2“ -12UNJ-3A
– Recommended Prefiltration: 20µ
– Recommended Inlet: 445 mm
– Recommended Outlet: 222,5 mm